A generator is only as reliable as the care you give it. Whether you use it as a backup power source during outages or run it regularly at a job site, one thing stays the same: a generator that isn’t maintained will let you down at the worst possible moment. The good news is that keeping your generator in top shape doesn’t require a service technician every time – most of the routine work can be done by the owner in 15-20 minutes.

This guide covers everything you should be checking and doing regularly, regardless of whether you own a compact inverter generator for home use or a more powerful unit for a workshop or commercial site.

Before Every Start: The Quick Checks

Before you fire up the generator – every single time – there are two things that take less than a minute and can save you from a serious and expensive breakdown.

Check the oil level. Pull the dipstick, wipe it clean, reinsert it fully, and check the reading. The oil should sit between the MIN and MAX marks. If it’s low, top it up before starting. Running a generator on low oil is one of the most common causes of engine damage, and it happens fast – an overheated, oil-starved engine can seize within minutes.

Check the fuel. This sounds obvious, but also check the quality of what’s in the tank. Petrol that has been sitting for more than 30 days starts to degrade, especially in warm weather. Degraded fuel leaves deposits in the carburetor and fuel lines, causes hard starting, and leads to rough, unstable operation. If the generator has been sitting unused, drain the old fuel and refill with fresh.

Every 50-100 Hours: The Core Maintenance

This is the interval that matters most. Most generator manufacturers – including Dekaf – recommend a full service check every 50 to 100 hours of operation, or at least once a year even if the generator hasn’t been used that much.

Oil Change

Engine oil doesn’t just lubricate – it also cleans and cools internal components. Over time it breaks down, accumulates combustion byproducts, and loses its protective properties. Old, dirty oil means more friction, more heat, and a shorter engine life.

Change the oil at the recommended interval using the grade specified in your generator’s manual. Don’t substitute with whatever is available – oil viscosity and type matter for engine longevity. Drain the old oil while the engine is still slightly warm (but not hot), as it flows out more completely and carries more contaminants with it.

Air Filter

The air filter protects the engine from dust, dirt, and debris. A clogged air filter restricts airflow, which causes the engine to run rich – burning more fuel than necessary, producing more exhaust, and generating excess heat. In dusty environments (construction sites, agricultural settings), the filter may need attention more frequently than the standard interval.

Foam filters can often be cleaned with warm soapy water, dried thoroughly, and lightly oiled before reinstalling. Paper filters generally need replacement rather than cleaning.

Fuel Filter

The fuel filter catches sediment and water that can enter from the tank or from the fuel itself. A blocked or contaminated fuel filter causes hard starting, power loss, and erratic engine behavior. Replace it at the recommended interval – it’s an inexpensive part that does an important job.

Spark Plugs (Petrol and Inverter Generators)

Spark plugs wear over time. The electrode gap widens, deposits build up on the tip, and ignition becomes less reliable. Signs of a worn spark plug include hard starting, rough idle, and increased fuel consumption. Check the gap against the specification in your manual, clean off deposits if possible, and replace if the electrode shows significant wear or if the plug is past its service life.

Dekaf petrol and inverter generators use standard, widely available spark plug types – replacements are easy to source and the swap takes minutes.

Cooling System: Don’t Ignore It

Air-Cooled Generators

Most portable and home-use generators – including the compact Dekaf petrol and inverter models – use air cooling. The engine relies on airflow through fins and vents to stay at a safe operating temperature. Over time, dust, grass clippings, and debris clog these vents and restrict cooling.

Inspect the cooling fins and air intake regularly. Use compressed air or a soft brush to clear any buildup. Never operate the generator in an enclosed space or with anything obstructing the vents – poor airflow leads directly to overheating, which causes permanent engine damage.

Liquid-Cooled Generators

Larger stationary and industrial generators typically use liquid cooling. For these units, check the coolant level regularly and inspect the hoses, clamps, and radiator for leaks or deterioration. Coolant should be replaced on the schedule specified in the manual – old coolant loses its corrosion inhibitors and can damage the cooling system from the inside.

Battery: The Weak Link for Electric-Start Models

If your generator has an electric start, the battery is the one component most likely to fail at an inconvenient time. Batteries lose charge when not in use, especially in cold weather, and their capacity degrades with age.

Check the battery charge every month. Keep the terminals clean and free of corrosion – a paste of baking soda and water works well for removing white oxide buildup. Tighten any loose terminal connections. Before winter, test the battery under load; if it struggles, replace it before the cold arrives rather than after the first power outage.

For Dekaf generators with electric start, a battery maintainer or trickle charger connected during long periods of storage keeps the battery at full capacity without overcharging it.

Electrical Connections: The Hidden Problem

Electrical connections loosen over time from vibration. Oxidation builds up on terminals and creates resistance, which causes voltage drop, heat buildup, and in serious cases – short circuits.

Every few months, inspect all accessible wiring, connectors, and terminals. Look for frayed insulation, signs of heat damage (discoloration or melted plastic), and any corrosion. Tighten any loose connections. If you find damaged wiring, have it repaired before operating the generator again – electrical faults are a fire risk.

Monthly Test Run: Even When You Don’t Need It

A generator that sits unused for months is not a generator you can rely on. Seals dry out, fuel system components gum up, the battery self-discharges, and you may not discover any of these problems until you actually need power.

Run the generator under load for at least 20-30 minutes every month. This circulates fresh oil through the engine, keeps the battery charged, exercises the fuel system, and gives you a chance to spot any issues before they become emergencies. For home backup generators, connecting a few appliances during the test run provides a realistic load and confirms the output is clean and stable.

Maintenance by Generator Type

Different generator technologies have slightly different priorities:

Petrol generators need the most attention to the fuel system. Petrol degrades faster than diesel, carburetors are more sensitive to stale fuel, and spark plugs need regular inspection. If storing for more than a month, use a fuel stabilizer or drain the carburetor completely.

Inverter generators – like the compact Dekaf inverter models – share the same basic engine care requirements as conventional petrol generators, but the inverter electronics add sensitivity to overheating. Keep cooling vents clear and never exceed the rated load. The advantage is fuel efficiency and clean output, but this comes with electronics that need to stay cool.

Diesel generators are more tolerant of extended operation but require careful attention to the fuel system. Diesel can grow biological contamination (algae) in the tank during long storage. Injectors need periodic cleaning or professional service. On the plus side, diesel engines generally have longer service intervals and a higher overall lifespan than petrol equivalents.

Gas generators have fewer fuel-related issues – gas doesn’t degrade in storage the way liquid fuels do. However, the gas supply system requires regular inspection: check all fittings and connections for leaks (use soapy water – bubbles indicate a leak), and inspect the regulator condition and gas filter.

Industrial and standby generators have the most complex maintenance schedules. Liquid cooling systems, automatic transfer switches, battery backup systems, and load bank testing all need to be part of a scheduled program. For these units, professional servicing at regular intervals is strongly recommended alongside owner-performed daily and weekly checks.

Simple Maintenance Schedule: Quick Reference

Task Frequency
Check oil level Before every start
Check fuel quality and level Before every start
Inspect air vents and cooling fins Monthly
Test run under load Monthly
Check battery charge and terminals Monthly
Inspect electrical connections Every 3 months
Change engine oil Every 50-100 hours
Replace air filter Every 100-200 hours
Replace fuel filter Every 100-200 hours
Inspect / replace spark plugs Every 100-200 hours
Check coolant level (liquid-cooled) Monthly
Full professional service Annually

What Happens When You Skip Maintenance

The consequences of neglect are predictable and expensive. Skipping oil changes leads to premature engine wear and eventual seizure. Dirty filters cause overheating and high fuel consumption. A flat battery means the generator won’t start when you need it. Loose electrical connections cause voltage instability that can damage connected equipment.

More importantly: a generator that fails during a power outage or on a job site isn’t just an inconvenience – it can mean no heating in winter, no refrigeration for perishables, lost productivity, or disrupted critical equipment.

A well-maintained generator, on the other hand, starts reliably, runs efficiently, and lasts significantly longer than one that’s neglected. Dekaf generators are built with quality components and reasonable service intervals – but no generator maintains itself.

Final Thought

Routine maintenance is not complicated. Most of what’s described here takes less time than filling a car with petrol. The discipline of checking oil before every start, changing fluids on schedule, and running a monthly test is what separates a generator that works from one that doesn’t.

If you’re unsure about any aspect of servicing your specific Dekaf model, refer to the user manual or contact us directly – we’re happy to walk you through the right intervals and procedures for your unit.